000015747 001__ 15747
000015747 005__ 20161115135328.0
000015747 04107 $$aeng
000015747 046__ $$k2013-06-12
000015747 100__ $$aSaisi, A.
000015747 24500 $$aPost-Earthquake Assessment of a Masonry Tower By  on - Site Inspection and Operational Modal Testing

000015747 24630 $$n34.$$pComputational Methods in Structural Dynamics and Earhquake Engineering
000015747 260__ $$bNational Technical University of Athens, 2013
000015747 506__ $$arestricted
000015747 520__ $$2eng$$aThe paper describes the methodology applied to assess the state of preservation of the tallest historic tower in Mantua, the "Gabbia" tower, after the earthquakes of May 2012. An extensive investigation programme  including visual inspection, sonic and flat jack tests, operational modal testing and structural modelling  has been planned to support the future preservation actions of the tower. The paper focuses especially on the information collected during on-site survey and dynamic tests and describes how these results can be employed and cross-correlated to assess the structural condition and seismic vulnerability of the tower.

000015747 540__ $$aText je chráněný podle autorského zákona č. 121/2000 Sb.
000015747 653__ $$aEarthquake, Masonry Towers, On-site Survey, Operational Modal Testing

000015747 7112_ $$aCOMPDYN 2013 - 4th International Thematic Conference$$cIsland of Kos (GR)$$d2013-06-12 / 2013-06-14$$gCOMPDYN2013
000015747 720__ $$aSaisi, A.$$iGentile, C.$$iCantini, L.
000015747 8560_ $$ffischerc@itam.cas.cz
000015747 8564_ $$s1470636$$uhttp://invenio.itam.cas.cz/record/15747/files/1388.pdf$$yOriginal version of the author's contribution as presented on CD, section: CD-MS 21 SEISMIC BEHAVIOUR AND RETROFITTING OF MONUMENTS AND HISTORICAL BUILDINGS
.
000015747 962__ $$r15525
000015747 980__ $$aPAPER