THERMOACOUSTICS


Abstract eng:
The thermoacoustic energy conversion systems can operate as heat pumps (or refrigerators which are based on the same principle) or prime movers. The design optimization of the thermoacoustic refrigerator was made using two methods, namely the optimization based on the cooling load maximization and on the coefficient of performance (COP) maximization. The highest COP can be achieved with the noble gas mixture helium-xenon (62%-38%) as the working fluid, while the highest cooling load can be achieved with pure helium.

Publisher:
Institute of Thermomechanics AS CR, v.v.i., Prague
Conference Title:
Conference Title:
Engineering Mechanics 2007
Conference Venue:
Svratka (CZ)
Conference Dates:
2007-05-14 / 2007-05-17
Rights:
Text je chráněný podle autorského zákona č. 121/2000 Sb.



Record appears in:



 Record created 2014-10-24, last modified 2014-11-18


Original version of the author's contribution as presented on CD, . :