000001904 24500 $$aEXPERIMENTAL STUDY OF THE FLOW FIELD IN T-JUNCTION MODEL USING PIV METHOD 

000001904 24630 $$n17.$$pEngineering Mechanics 2011
000001904 260__ $$bInstitute of Thermomechanics AS CR, v.v.i., Brno
000001904 506__ $$arestricted
000001904 520__ $$2eng$$aReported here is the experimental study in the pipe line element T-junction. The velocity fields were measured by PIV method with 3-camera alignment. This alignment makes accessible T-junction areas covered by image distortions and refraction irregularities in drilled glass block. Four basic connection regimes are studied with flow ratios into inlet branches in turn. Flow field is described with a numerical vector maps and presented as scalar maps with streamlines. Velocity profiles in the inlet and outlet branches are generated. Visualizations of the flow with streamlines and vector fields provide the basic characteristic of flows mixing, separations, vorticities etc. Analyzed datasets are used for evaluation and verification of numerical models.

000001904 540__ $$aText je chráněný podle autorského zákona č. 121/2000 Sb.
000001904 653__ $$aT-junction, PIV, measurement, calibration.

000001904 7112_ $$aEngineering Mechanics 2011$$cSvratka (CZ)$$d2011-05-09 / 2011-05-12$$gEM2011
000001904 720__ $$aKotek, M.$$iKopecký, V.$$iJašíková, D.