INFLUENCE OF ECCENTRICITY ON THE AXIAL FLOW IN LEAKAGE JOINTS
Abstract eng: This article is concerned with comparison of velocity field size depending on size of the eccentricity in leakage joints of centrifugal pumps. Eccentricity is created by gravitation and radial force from impeller. This report describes approach for calculating the straight seal without rotation. An eccentricity dependence of the axial velocity field in the article is numerically verified by using FLUENT software.