000019523 520__ $$2eng$$aThis paper presents the seismic isolation system incorporating high strength reinforced concrete (RC) core walls and precast concrete perimeter frames. As the seismic isolation devices, 42 seismic isolation rubber bearings and 10 oil dampers are installed on the isolation floor. The structural robustness is reflected into the seismic criteria which can be achieved by the tube structure combined seismic isolation system with notably rigid superstructure utilizing RC core walls. Seismic criteria are categorized into two levels of earthquakes: Level 1 earthquakes and Level 2 earthquakes. Level 1 earthquakes are denoted as rarely occurred earthquakes with 50-year return period, which can occur several times in building service period. Level 2 earthquakes, on the other hand, are denoted as extremely rarely occurred earthquakes with 500-year return period, which can occur one time in building service period. To guarantee the high seismic resistant performances, all member stresses are supposed to be less than or equals to short-term allowable stresses and story drift is limited to less than 1/300 in the event of Level 2 earthquakes. Seismic performances of the building are evaluated based on nonlinear time history analyses using Multi-Degree-ofFreedom (MDF) model with bending and shear springs in each story and sway-rocking springs on the isolation floor. The 3D frame model for nonlinear static pushover analyses is composed simultaneously to evaluate the validity of analyses results based upon MDF model.

000019523 540__ $$aText je chráněný podle autorského zákona č. 121/2000 Sb.
000019523 653__ $$aSeismic isolation system, Reinforced concrete core wall, Precast concrete perimeter frame

000019523 7112_ $$a16th World Conference on Earthquake Engineering$$cSantiago (CL)$$d2017-01-09 / 2017-01-13$$gWCEE16
000019523 720__ $$aShimazaki, Dai
000019523 8560_ $$ffischerc@itam.cas.cz
000019523 8564_ $$s958164$$uhttp://invenio.itam.cas.cz/record/19523/files/3830.pdf$$yOriginal version of the author's contribution as presented on USB, paper 3830.
000019523 962__ $$r16048
000019523 980__ $$aPAPER