CHANGING THE BEHAVIOR OF MR FLUIDS DURING LONG TERM OPERATION


Abstract eng:
The article describes results of durability test of a magnetorheological fluid (MRF) which was carried out in a custom design rheometer. The rheometer design allows measurement of the rheological properties of MR fluid and its exposure to a long-term loading simultaneously, without any manipulation of the measured sample. Owing to this, changes of the two most important parameters describing the behavior of MR fluids - dynamic viscosity and yield stress - could be followed during the durability test. The dependence of yield stress and dynamic viscosity on temperature and magnetization current was evaluated. The results show a significant change of the yield strength (500%) during the durability test. Independence of the yield stress on the temperature was conclusively proven. The viscosity decreased by 35% from its initial value after dissipation of 9000kJ out of total 119000kJ and then remained the same until the end of the durability test. Viscosity dependence on temperature was evaluated.

Contributors:
Publisher:
Institute of Thermomechanics AS CR, v.v.i., Brno
Conference Title:
Conference Title:
Engineering Mechanics 2011
Conference Venue:
Svratka (CZ)
Conference Dates:
2011-05-09 / 2011-05-12
Rights:
Text je chráněný podle autorského zákona č. 121/2000 Sb.



Record appears in:



 Record created 2014-10-24, last modified 2014-11-18


Original version of the author's contribution as presented on book, page 519. :
Download fulltext
PDF

Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)