ALTERNATIVE ANCHORAGE SYSTEMS FOR TEXTILE REINFORCED CONCRETE ELEMENTS


Abstract eng:
The main reason for the thickness of a concrete sandwich element is the requirement for the protective concrete cover for the steel reinforcement. Use of textile reinforced concrete (TRC) makes it possible to produce much thinner and slimmer concrete facades in the future without changing their mechanical properties. The focus of this study was to produce and test various alternative non-corrosive anchorage systems between a TRC thin façade element, an insulation layer and a load bearing element. Most of the tested anchorage systems gave satisfactorily results offering a more sustainable solution to the current technology.

Contributors:
Publisher:
Japan Concrete Institute, Tokyo
Conference Title:
Conference Title:
First International Conference on Concrete Sustainability
Conference Venue:
Tokyo (JP)
Conference Dates:
2013-05-27 / 2013-05-29
Rights:
Text je chráněný podle autorského zákona č. 121/2000 Sb.



Record appears in:



 Record created 2014-10-29, last modified 2014-11-18


Original version of the author's contribution as presented on CD, . :
Download fulltext
PDF

Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)