EXPERIMENTAL VERIFICATION OF DAMAGE LOCATION TECHNIQUES FOR FRAME STRUCTURES ASSEMBLED USING BOLTED CONNECTIONS


Abstract eng:
This work is focused on experimental verification of existing techniques for localization of a loosened bolted connection. To this end, a laboratory-scale 2-meter-long steel frame is used. The structure consists of 11 steel beams forming a four-bay frame, which is subjected to impact loads using a modal hammer. The accelerations are measured at 20 different locations on the frame, including joints and beam elements. Two states of the structure are considered: a healthy and a damaged one. The damage is introduced by means of loosening two out of three bolts at one of the frame connections. Experimental modal analysis reveals that the loosened bolts in the connection cause a shift only in some of the frame’s natural frequencies, while the others remain insensitive to the damage.