ANALYSIS OF DAMAGED CONNECTION PIPING
Abstract eng: The following paper analyses a cracking of a superheater connection piping which occurred after a general repair. Pipes repeatedly detached in the area of welding to the collector nozzles. Connection piping was subjected to a thorough FEM analysis and flow simulation using CFD software.