NUMERICAL MODELLING OF THE DESTRUCTION OF THE REINFORCEMENT BARS IN THE SUPPORTING ZONE OF THE COLUMN


Abstract eng:
The destruction of the supporting zone of slab-column structures caused by a breakdown, pulls the upper reinforcement in the course of the dropping down of the roof upwards. The only element which can deter a further catastrophe is the reinforcement at the bottom, which is not torn off, but even pressed against the concrete of the column and the slab. The paper presents the results of laboratory tests performed on a simplified model of a slab-column connection. The aim of investigations was to find out at which value of the load the destruction of such a connection occurs due to the rupture of the bars above the column. Basing on these investigations a numerical model was developed in the ANSYS program. In order to render the conditions of connecting the reinforced concrete element with the reinforcement bars in the case of considerable deformations, the model was divided into finite elements. In modelling the fragment of the connection of reinforcement bars with the concrete and anchoring, the contacting elements were used. The obtained results of laboratory tests and the results of numerical calculations permitted to determine the relations between the exerted load and the displacement of the column in time and also to determine the values of the force at which the breakdown of the bars above the column had taken place.

Publisher:
Brno University of Technology- Institute of Solid Mechanics, Mechatronics and Biomechanics
Conference Title:
Conference Title:
Engineering Mechanics 2014
Conference Venue:
Svratka (CZ)
Conference Dates:
12/05/2014 - 15/05/2014
Rights:
Text je chráněný podle autorského zákona č. 121/2000 Sb.



Record appears in:



 Record created 2014-12-04, last modified 2014-12-04


Original version of the author's contribution as presented on CD, paper No. 167.:
Download fulltext
PDF

Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)