000010543 001__ 10543
000010543 005__ 20141205155738.0
000010543 04107 $$aeng
000010543 046__ $$k2008-10-12
000010543 100__ $$aKohara, Katsuhiko
000010543 24500 $$aA Study on Evaluation of Seismic Performances of Retrofitting with Siding Board for Existing Timber Buildings

000010543 24630 $$n14.$$pProceedings of the 14th World Conference on Earthquake Engineering
000010543 260__ $$b
000010543 506__ $$arestricted
000010543 520__ $$2eng$$aIt aims to mention about the various examinations to use an exterior siding material as a retrofitting method of construction of the existent buildings. The retrofitting methods of construction of 2 case are proposed. In the Case 1 method, the siding is changed of the existent wall of the range (about 2.0m) that a part reaches ground floor. In this case, a foothold cost can be reduced. In the Case 2 method, a thickness siding (t= 24 mm) is raised even on the beam. In this case, it works for the improvement in the seismic performance and the fireproof performance. Because a proof stress element and finishing can be included, a restructuring cost can be reduced. And an amount of money assumption is made in the precision which it has in advance in the foundation of the reinforcement part as well because it can be confirmed. Finishing can plan the improvement which sometimes has more than one variation by adding a color pattern in result fine sight as well, too. It can think that execution becomes possible with being here confidently because it is the outside construction. The static loading test is enforced all 26 specimens. In the Case 1, NS001 (width 455 mm, t=18mm) has 2.4 of the wall magnification, NS003 (width 910 mm, 2 sheets-folds of t=12mm) has 3.6, the type (NS010, NS011 and NS013) which drip reinforcement have 3.4 - 4.5. In the Case 2, NS009 (width 910 mm, 2 sheets-folds of t= 12 mm) and NS026 (width 910 mm, t=16mm) have 12.0 of the wall magnification, NS008 (width 455 mm, t=18mm) and NS025 (width 455 mm, t=24mm) have about 4.8 - 5.5. And a narrow house is applied the Case

000010543 540__ $$aText je chráněný podle autorského zákona č. 121/2000 Sb.
000010543 653__ $$aSeismic Performance, Retrofitting, Siding Board, Bearing Wall

000010543 7112_ $$a14th World Conference on Earthquake Engineering$$cBejing (CN)$$d2008-10-12 / 2008-10-17$$gWCEE15
000010543 720__ $$aKohara, Katsuhiko$$iKomoto, Kazuyoshi$$iTakahashi, Asuka$$iFukumoto, Mitsuo$$iHagiwara, Shintaro$$iMiyazawa, Kenji
000010543 8560_ $$ffischerc@itam.cas.cz
000010543 8564_ $$s253280$$uhttps://invenio.itam.cas.cz/record/10543/files/05-04-0039.pdf$$yOriginal version of the author's contribution as presented on CD, Paper ID: 05-04-0039.
000010543 962__ $$r9324
000010543 980__ $$aPAPER