000010846 001__ 10846
000010846 005__ 20141205155809.0
000010846 04107 $$aeng
000010846 046__ $$k2008-10-12
000010846 100__ $$aMahmood, Hamid
000010846 24500 $$aMonotonic Testing of Unreinforced and FRP-Retrofitted Masonry Walls Prone to Shear Failure in an Earthquake

000010846 24630 $$n14.$$pProceedings of the 14th World Conference on Earthquake Engineering
000010846 260__ $$b
000010846 506__ $$arestricted
000010846 520__ $$2eng$$aA research programme has been initiated in New Zealand to address concerns regarding the seismic performance of New Zealand’s unreinforced masonry (URM) building stock. As a component of this programme, monotonic in-plane shear (diagonal compression) tests were conducted on URM wallettes to simulate the commonly observed diagonal shear failure of in-plane walls in an earthquake. In total, four wallettes were tested, three of which were retrofitted with various configurations of GFRP strips. The unretrofitted wallette failed in a brittle manner. The retrofitted wallettes exhibited a more ductile behaviour. Significant increases in wallette strength and pseudo-ductility were achieved by the application of GFRP.

000010846 540__ $$aText je chráněný podle autorského zákona č. 121/2000 Sb.
000010846 653__ $$aGFRP, retrofit, seismic, shear, testing

000010846 7112_ $$a14th World Conference on Earthquake Engineering$$cBejing (CN)$$d2008-10-12 / 2008-10-17$$gWCEE15
000010846 720__ $$aMahmood, Hamid$$iRussell, Alistair P.$$iIngham, Jason M.
000010846 8560_ $$ffischerc@itam.cas.cz
000010846 8564_ $$s1154914$$uhttps://invenio.itam.cas.cz/record/10846/files/12-01-0216.pdf$$yOriginal version of the author's contribution as presented on CD, Paper ID: 12-01-0216.
000010846 962__ $$r9324
000010846 980__ $$aPAPER