000010904 520__ $$2eng$$aWe developed a methodology of the seismic isolation for retrofitting a group of buildings in one unit using post-tensioned cables, and evaluated their safety and functionary based on the performance based design. We applied this methodology to two large-scale buildings of Hamamatsu Medical Center, which are the first hospital retrofitted by the seismic isolation in Japan. The two buildings are both steel-reinforced concrete frame structures of the nine-story on the ground and the one-story on the underground level. They were constructed in 1973 and 1975, based on the old building code before 1981. In the proposed retrofit scheme, the two buildings were integrated into one structural unit by connecting together at each floor by using post-tensioned cables through slabs. We confirmed that the integration worked well by comparing microtremors of the buildings before and after the integration. Seismic isolation devices were set up mainly in columns of the underground level. We adopted the temporary supporting method using post-tensioned units to install the devices safely and economically (Masuzawa et al., 2004). In the seismic design phase, we first simulated the broadband input earthquake ground motions for a hypothetical M8-class earthquake in the vicinity of the site, using a hybrid method (Hisada, 2000, etc.). Finally, we confirmed the safety and functionary of the medical center by evaluating the seismic performance of the buildings, based on the time history seismic response analysis.

000010904 540__ $$aText je chráněný podle autorského zákona č. 121/2000 Sb.
000010904 653__ $$aSeismic isolation retrofit, Structural integration of buildings, Medical complex, Performance-based design, Site-specific strong ground motion prediction

000010904 7112_ $$a14th World Conference on Earthquake Engineering$$cBejing (CN)$$d2008-10-12 / 2008-10-17$$gWCEE15
000010904 720__ $$aMasuzawa, Yoe$$iHisada, Yoshiaki
000010904 8560_ $$ffischerc@itam.cas.cz
000010904 8564_ $$s483765$$uhttps://invenio.itam.cas.cz/record/10904/files/S05-01-016.pdf$$yOriginal version of the author's contribution as presented on CD, Paper ID: S05-01-016.
000010904 962__ $$r9324
000010904 980__ $$aPAPER