000010918 100__ $$aMatsuo, A.
000010918 24500 $$aUpgrading the Deformation Capacity of Anchor-Bolts in the Exposed-Type Column Bases of Existing Old Steel Structures

000010918 24630 $$n14.$$pProceedings of the 14th World Conference on Earthquake Engineering
000010918 260__ $$b
000010918 506__ $$arestricted
000010918 520__ $$2eng$$aA main reason for early tensile brittle fracture of the anchor-bolts in the steel exposed-type column bases under the past earthquake is that the thread part has the decreased sectional area of 75% of the regular part of the anchor-bolt. Many existing old steel structures in Japan might contain such anchor-bolts whose deformation capacity is very poor and urgent diagnosis and upgrading is needed. This study proposes the method of upgrading the performance of anchor-bolts in existing old steel structures. A high-strength bolt equivalent to F14T is screwed to reinforce the thread part, after the hole is emptied from the top of the anchor bolt. This paper shows the performance of the upgraded anchor-bolts through the experimental studies.

000010918 540__ $$aText je chráněný podle autorského zákona č. 121/2000 Sb.
000010918 653__ $$aDeformation capacity, Tensile test, Pull-out Test,Upgrading,Exposed-type column base

000010918 7112_ $$a14th World Conference on Earthquake Engineering$$cBejing (CN)$$d2008-10-12 / 2008-10-17$$gWCEE15
000010918 720__ $$aMatsuo, A.$$iSawada, K.$$iYamamoto, K.$$iTakamatsu, T.$$iTamai, H.