000011322 24500 $$aExperimental Investigation on the Interaction of Reinforced Concrete Frames with Precast-Prestressed Concrete Floor Systems

000011322 24630 $$n14.$$pProceedings of the 14th World Conference on Earthquake Engineering
000011322 260__ $$b
000011322 506__ $$arestricted
000011322 520__ $$2eng$$aA three dimensional, approximately half scale experimental test has been carried out to investigate the effect of precast-prestressed floor units on the seismic performance of reinforced concrete moment resisting frames. This paper gives an overview of the experiment and summarizes the results obtained from the test. The paper focuses on the level of strength enhancement and elongation within the plastic hinges. The results show that the presence of prestressed floor units partially restrains elongation of plastic hinges such that elongation in the exterior and interior plastic hinges differs significantly. This increases the strength of the beams more than that specified in the major structural design codes. This is a cause of great concern as this underestimation of beam strength may result in brittle column failure modes in a major earthquake.

000011322 540__ $$aText je chráněný podle autorského zákona č. 121/2000 Sb.
000011322 653__ $$aReinforced concrete moment resisting frames, precast-prestressed concrete floor, beam elongation, flange effect, strength enhancement

000011322 7112_ $$a14th World Conference on Earthquake Engineering$$cBejing (CN)$$d2008-10-12 / 2008-10-17$$gWCEE15
000011322 720__ $$aPeng, Brian H.H.$$iDhakal, Rajesh P.$$iFenwick, Richard C.$$iCarr, Athol J.$$iBull, D.K.
000011322 8560_ $$ffischerc@itam.cas.cz
000011322 8564_ $$s632876$$uhttps://invenio.itam.cas.cz/record/11322/files/12-01-0042.pdf$$yOriginal version of the author's contribution as presented on CD, Paper ID: 12-01-0042.
000011322 962__ $$r9324
000011322 980__ $$aPAPER