000011337 001__ 11337
000011337 005__ 20141205155900.0
000011337 04107 $$aeng
000011337 046__ $$k2008-10-12
000011337 100__ $$aPetti, Luigi
000011337 24500 $$aSmall Scale Experimental Testing to Verify the Effectiveness of the Base Isolation and Tuned Mass Dampers Combined Control Strategy

000011337 24630 $$n14.$$pProceedings of the 14th World Conference on Earthquake Engineering
000011337 260__ $$b
000011337 506__ $$arestricted
000011337 520__ $$2eng$$aThis paper presents the most significant results obtained within a broad range of experimental tests aimed at evaluating both the effectiveness and robustness of the Base Isolation (BIS) and Tuned Mass Damper (TMD) combined control strategy (BIS&TMD). After a brief description of the experimental model set-up, the paper describes the identification procedures for the fixed base structure, the base isolated structure and the base isolated structure equipped with a mass damper system. The main experimental results, representing the dynamic response of a small-scale model to scaled recorded earthquake excitations, are later presented and discussed. Finally, the effectiveness and robustness of the combined control strategy is investigated by comparing the model’s dynamic response, in particular the reduction in relative displacements and absolute accelerations due to the application of different mass damping systems are evaluated.

000011337 540__ $$aText je chráněný podle autorského zákona č. 121/2000 Sb.
000011337 653__ $$aBase Isolation, Mass Damper, Hybrid Control, Experimental Test

000011337 7112_ $$a14th World Conference on Earthquake Engineering$$cBejing (CN)$$d2008-10-12 / 2008-10-17$$gWCEE15
000011337 720__ $$aPetti, Luigi$$iGiannattasio, Giovanni$$iDe Iuliis, Massimiliano
000011337 8560_ $$ffischerc@itam.cas.cz
000011337 8564_ $$s374200$$uhttps://invenio.itam.cas.cz/record/11337/files/12-02-0004.pdf$$yOriginal version of the author's contribution as presented on CD, Paper ID: 12-02-0004.
000011337 962__ $$r9324
000011337 980__ $$aPAPER