000011878 24500 $$aExperimental Study on a New Precast Post-Tensioned Concrete Beam Column Connection System

000011878 24630 $$n14.$$pProceedings of the 14th World Conference on Earthquake Engineering
000011878 260__ $$b
000011878 506__ $$arestricted
000011878 520__ $$2eng$$aThe objectives of this study were to investigate the hysteresis characteristics, shear transferring capacity, damage state and possibility to disassemble the precast unbonded post-tensioned connections with and without shear bracket under the simultaneous cyclic load and large gravity load. Three half-scale specimens of precast unbonded post-tensioned exterior beam-column connection of large span frame was proposed and tested. The test results of the specimen without shear bracket showed excessive beam slip, resulted in large residual deformation, while the specimens with shear bracket that have the amount of prestressed steel 50% less than that of the specimen without shear bracket expressed very good performance with very small residual deformation, almost no slip, minor damage to the beam and column elements, and easy to disassemble even after experienced the story drift up to 6% drift.

000011878 540__ $$aText je chráněný podle autorského zákona č. 121/2000 Sb.
000011878 653__ $$aPrecast concrete, Post-tensioned, Exterior beam column connection, Shear friction.

000011878 7112_ $$a14th World Conference on Earthquake Engineering$$cBejing (CN)$$d2008-10-12 / 2008-10-17$$gWCEE15
000011878 720__ $$aThinh, Do Tien$$iKusunoki, Koichi$$iTasai, Akira
000011878 8560_ $$ffischerc@itam.cas.cz
000011878 8564_ $$s315549$$uhttps://invenio.itam.cas.cz/record/11878/files/05-01-0104.pdf$$yOriginal version of the author's contribution as presented on CD, Paper ID: 05-01-0104.