EXPERIMENTAL ANALYSIS OF SLENDER HPC COLUMNS AT THE STABILITY FAILURE


Abstract eng:
The European standard for design of compressed concrete members allows the use of non-linear calculations. The required reliability within design of slender members subjected to axial force and bending moment is not yet satisfyingly verified and confirmed for cases when the buckling failure precedes the breach in the critical cross-section. In order to verify and compare the reliability of the standard design methods, a comparison with experiment results is necessary. In cooperation with STRABAG Bratislava LTD, the Faculty of Civil Engineering at the Slovak University of Technology in Bratislava, carried out an applied research covering an experimental verification of slender high-performance concrete columns. In the following paper, the authors present the preparation and progress of the third series of experimental verifications for six slender high-performance concrete columns of the concrete strength class C80/95. The reinforcement and shape of the columns together with the initial eccentricity of axial force were designed so that the columns fail due to stability loss before reaching the resistance in the critical cross-section.

Contributors:
Publisher:
Institute of Thermomechanics AS CR, v.v.i., Praha
Conference Title:
Conference Title:
Engineering Mechanics 2016
Conference Venue:
Svratka, CZ
Conference Dates:
2016-05-09 / 2016-05-12
Rights:
Text je chráněný podle autorského zákona č. 121/2000 Sb.



Record appears in:



 Record created 2016-08-16, last modified 2016-08-16


Original version of the author's contribution as presented on CD, id 010, section REL.:
Download fulltext
PDF

Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)