000013449 24500 $$aRetrofitting by Base Isolation of Existing Buildings in Armenia and in Romania and Comparative Analysis of Innovative Vs. Conventional Retrofitting

000013449 24630 $$n3.$$pComputational Methods in Structural Dynamics and Earhquake Engineering
000013449 260__ $$bNational Technical University of Athens, 2011
000013449 506__ $$arestricted
000013449 520__ $$2eng$$aIn recent years seismic isolation technologies in Armenia were extensively applied in construction of new buildings, as well as in retrofitting of existing buildings. Three remarkable projects on retrofitting by base isolation are described in the paper. One of them is retrofitting of a 5-story stone apartment building. The operation was made without resettlement of the occupants. World practice provides no similar precedent in retrofitting of apartment buildings. The other project is retrofitting of the 60 years old non-engineered 3-story stone school building. This building has historical and architectural value. Unique operations which were carried out in order to install the isolation system within the basement of this building and to preserve its architectural appearance are described. Accumulated experience created a good basis for participation in the international competition announced by the Government of Romania for development of the design on retrofitting by base isolation of the 178 years old historical building of the Iasi City Hall. The structural concept, including the new approach on installation of seismic isolation rubber bearings in this building, is described and detailed results of the earthquake response analysis for two cases, i.e. when the building is base isolated and when it has a fixed base, are given. For all three buildings comparative analyses of innovative vs. conventional retrofitting are carried out. Different methods of conventional retrofitting are considered and their costs are compared with the cost of innovative retrofitting by base isolation.

000013449 540__ $$aText je chráněný podle autorského zákona č. 121/2000 Sb.
000013449 653__ $$aBase Isolation, Innovative Retrofitting, Existing Building, Conventional Retrofitting, Comparative Analysis, Cost Effectiveness

000013449 7112_ $$aCOMPDYN 2011 - 3rd International Thematic Conference$$cIsland of Corfu (GR)$$d2011-05-25 / 2011-05-28$$gCOMPDYN2011
000013449 720__ $$aMelkumyan, M.$$iMihul, V.$$iGevorgyan, E.