Importance of Permanent Ground Displacement on the Dynamic Response of a Bridge Crossing a Fault Rupture Zone


Abstract eng:
The effect of high-pass filtering on near-fault ground motion records is to completely eliminate the permanent ground displacement and significantly reduce the dynamic ground displacement. This may considerably influence the calculated seismic response of a spatially extended engineering structure crossing a fault rupture zone. To demonstrate the importance of incorporating permanent ground displacements in the analysis and design of extended structures under specific fault crossing conditions, the dynamic response of a seismically isolated bridge located in the vicinity of a surface fault rupture (“Case A”) or crossing a fault rupture zone (“Case B”) is calculated by utilizing a near-fault ground motion record processed with and without a displacement offset. The seismically isolated bridge considered in this study is a 10-span continuous structure supported by 11 piers, resembling a typical segment of the 2.3 km long Bolu Viaduct 1 located in westcentral Turkey. The Lucerne Valley record from the 1992 Mw 7.2 Landers earthquake, which preserves a permanent ground displacement in the fault-parallel direction and exhibits a large velocity pulse in the fault-normal direction, is used as the basis for investigating the effect of high-pass filtering on the dynamic response of the bridge. For the seismically isolated bridge located in the vicinity of the surface fault rupture (“Case A”), the utilization of the high-pass filtered ground motion leads to underestimating the demands of pier top, pier bottom and deck displacements. However, the demands of isolation displacement, isolation permanent displacement and pier drift – quantities associated predominantly with the dynamic response of the bridge – are almost identical for both the unfiltered and filtered versions of the ground motion record. On the other hand, for the seismically isolated bridge traversed by a fault rupture zone (“Case B”), all response quantities are significantly underestimated when the high-pass filtered ground motion is used. These results, though limited to a single bridge structure and a single ground motion input, clearly indicate the importance of permanent ground displacement on the dynamic response of spatially extended engineering structures crossing fault rupture zones.

Contributors:
Conference Title:
Conference Title:
16th World Conference on Earthquake Engineering
Conference Venue:
Santiago (CL)
Conference Dates:
2017-01-09 / 2017-01-13
Rights:
Text je chráněný podle autorského zákona č. 121/2000 Sb.



Record appears in:



 Record created 2017-01-18, last modified 2017-01-18


Original version of the author's contribution as presented on USB, paper 2363.:
Download fulltext
PDF

Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)