Seismic Assessment of Damaged Margherita Palace Using Applied Element Method


Abstract eng:
The Margherita Palace is a heritage masonry structure constructed two centuries ago in L’Aquila (Italy) and extensively damaged by the strong 2009 earthquake. The palace was considered unstable and therefore temporarily supported to avoid its collapse. A structural survey of the palace walls and floors was carried out using laser scanning. The laser scanning data was post-processed to create three dimensional model including the cracks and damage in the different structural elements. The paper discusses challenges dealing with both the laser scan data set and detected damage data to create a full 3-D Applied Element Model of the existing conditions of the building with cracking and material damage. The challenges include the removal of noise from the data, meshing challenges to create 3-D elements with acceptable aspect ratio and applying existing cracking and weakening to different components. Nonlinear dynamic analysis is performed for the damaged structure to check its partial or total collapse resistance if similar strong earthquake were to be applied to the structure, without the temporary supports, again. This analysis helps determining the weakest point of the structure which needs special retrofit attention.

Contributors:
Conference Title:
Conference Title:
16th World Conference on Earthquake Engineering
Conference Venue:
Santiago (CL)
Conference Dates:
2017-01-09 / 2017-01-13
Rights:
Text je chráněný podle autorského zákona č. 121/2000 Sb.



Record appears in:



 Record created 2017-01-18, last modified 2017-01-18


Original version of the author's contribution as presented on USB, paper 2399.:
Download fulltext
PDF

Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)