EFFECT OF VIBRO-INSULATION ON RESTRICTION OF VIBRATION TRANSFER FROM SUBSOIL INTO THE BUILDING


Abstract eng:
The solution of vibration transfer from the subsoil to the structure is demonstrated using the example of a multi-storey reinforced concrete building, founded on a dual foundation plate. An antivibration layer of rubber has been designed between the two plates. Two 3-D numerical models of the building take into account the individual storeys, firstly together with the lay-out of the rubber distribution in the foundation part and secondly without this rubber part. For response analysis, the measured time histories in the construction area were selected and then the typical response was used as an input for a dynamic analysis of the structure.

Contributors:
Publisher:
Institute of Thermomechanics AS CR, v.v.i., Brno
Conference Title:
Conference Title:
Engineering Mechanics 2011
Conference Venue:
Svratka (CZ)
Conference Dates:
2011-05-09 / 2011-05-12
Rights:
Text je chráněný podle autorského zákona č. 121/2000 Sb.



Record appears in:



 Record created 2014-10-24, last modified 2014-11-18


Original version of the author's contribution as presented on book, page 375. :
Download fulltext