000019540 100__ $$aChouw, Nawawi
000019540 24500 $$aInfluence of Liquefaction and the Interaction Between Adjacent Structures on Structural Responses

000019540 24630 $$n16.$$pProceedings of the 16th World Conference on Earthquake Engineering
000019540 260__ $$b
000019540 506__ $$arestricted
000019540 520__ $$2eng$$aDuring past decades the destructive potential and the complexity of soil liquefaction phenomenon associated with strong earthquakes has been widely documented. However, current structural seismic design generally neglects the influence of the subsoil. Design codes that deal with liquefaction usually focus the settlements that can affect the structural foundations. Additionally, most studies related to soil-structure interaction have focused on the response of an isolated structure. In reality, especially in urban areas, this assumption rarely can be justified. The omission of adjacent structures can lead to inaccurate results, especially when nonlinear behaviour of soil, e.g. resulting from liquefaction, takes place. The aim of this work was to implement a holistic approach to the study of liquefaction. The influence of an existing structure on the liquefaction potential will be presented. Also, the effects of adjacent structures on the seismic response will be investigated under conditions of liquefaction. To reach those goals, a series of physical experiments were performed in the centrifuge facilities of the Japanese Institute of Occupational Healthy and Safety (JNIOSH) in Tokyo. A laminar box was used to reduce boundary effects. Rigid blocks were used to represent the influence of a shallow foundation on the underlying soil. In order to achieve a homogeneous density, the sand was rained from a fixed height above the base of the box. Preliminary results show a higher settlement for a stand-alone structure compare with free-field condition. It was found that an adjacent structure had a significant influence of the response of the foundation soil

000019540 540__ $$aText je chráněný podle autorského zákona č. 121/2000 Sb.
000019540 653__ $$aCentrifuge test; Structure-soil-structure interaction; liquefaction; adjacent structures

000019540 7112_ $$a16th World Conference on Earthquake Engineering$$cSantiago (CL)$$d2017-01-09 / 2017-01-13$$gWCEE16
000019540 720__ $$aChouw, Nawawi$$iLarkin, Tam$$iBarrios, Gonzalo
000019540 8560_ $$ffischerc@itam.cas.cz
000019540 8564_ $$s417381$$uhttps://invenio.itam.cas.cz/record/19540/files/3859.pdf$$yOriginal version of the author's contribution as presented on USB, paper 3859.
000019540 962__ $$r16048
000019540 980__ $$aPAPER