COMPARING TURBULENCE MODELS FOR GAS-PARTICLE MIXTURE PNEUMATIC CONVEYING


Abstract eng:
The system of transport tertiary air in cement kiln installation is one of the elements, which has the very large influence on production processing. This paper analyses numerical calculation in the installation for tertiary air in a cement plant. The operation condition of the installation is to ensure transport of gas with the smallest number of particles. By comparing several turbulence models used for calculation gas phase motion and Lagrangian model for discrete phase one can find an optimal solution. The particle trajectories depend on velocity field in researched models. For analyzed examples, the same pressure drop between inlet and outlet to the tertiary air duct were set.

Contributors:
Publisher:
Brno University of Technology, Institute of Solid Mechanics, Mechatronics and Biomechanics, Brno
Conference Title:
Conference Title:
Engineering Mechanics 2017
Conference Venue:
Svratka, CZ
Conference Dates:
2017-05-15 / 2017-05-18
Rights:
Text je chráněný podle autorského zákona č. 121/2000 Sb.



Record appears in:



 Record created 2017-05-22, last modified 2017-05-22


Original version of the author's contribution in proceedings, page 202, section FLU.:
Download fulltext
PDF

Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)