000021369 100__ $$aMarcián, P.
000021369 24500 $$aANALYSIS OF BOUNDARY CONDITIONS IN FINITE ELEMENT SUB-MODELS OF INTERACTION OF HUMAN MANDIBLE WITH DENTAL IMPLANT

000021369 24630 $$n23.$$pEngineering Mechanics 2017
000021369 260__ $$bBrno University of Technology, Institute of Solid Mechanics, Mechatronics and Biomechanics, Brno
000021369 506__ $$arestricted
000021369 520__ $$2eng$$aThis paper deals with the computational modelling of dental implant interacting with bone tissue. For the purposes of the study, one human mandible and a segment of a different human mandible were examined. In total, five variants of geometry models with dental implant were investigated: One full mandible and four segments. For the latter, two different boundary conditions were used (first based on the submodeling approach and second assuming fixed support). If the coarse model for the particular bone segment model is not available, it is possible to use a generic boundary condition for a typical mandible subjected to a typical loading.

000021369 540__ $$aText je chráněný podle autorského zákona č. 121/2000 Sb.
000021369 653__ $$aBiomechanics, FEM, Dental Implant, Sub-modeling.

000021369 7112_ $$aEngineering Mechanics 2017$$cSvratka, CZ$$d2017-05-15 / 2017-05-18$$gEM2017
000021369 720__ $$aMarcián, P.$$iBorák, L.$$iHoráčková, L.$$iFlorian, Z.