000021400 001__ 21400
000021400 005__ 20170522124353.0
000021400 04107 $$aeng
000021400 046__ $$k2017-05-15
000021400 100__ $$aOsowski, P.
000021400 24500 $$aVERYFICATION OF VELOCITY MESURMENT METHODS BY HIGH SPEED CAMERA AND ACCELEROMETER ON EXAMPLE OF IMPACT TESTER

000021400 24630 $$n23.$$pEngineering Mechanics 2017
000021400 260__ $$bBrno University of Technology, Institute of Solid Mechanics, Mechatronics and Biomechanics, Brno
000021400 506__ $$arestricted
000021400 520__ $$2eng$$aIn the paper the velocity measurement accuracy analysis of impact testers dropping platen is shown. The measurement is carried out by two devices: accelerometer and high speed camera. During research it was assumed that dropping platen is moving in uniformly accelerated motion. The uncertainty of velocity measurement for each method was determined depending on the sampling frequency of measuring devices and the free fall height of dropping platen.

000021400 540__ $$aText je chráněný podle autorského zákona č. 121/2000 Sb.
000021400 653__ $$aLinear velocity measurement, Uncertainty measurement, Impact tester.

000021400 7112_ $$aEngineering Mechanics 2017$$cSvratka, CZ$$d2017-05-15 / 2017-05-18$$gEM2017
000021400 720__ $$aOsowski, P.$$iPiatkowski, T.$$iWolski, M.
000021400 8560_ $$ffischerc@itam.cas.cz
000021400 8564_ $$s829066$$uhttps://invenio.itam.cas.cz/record/21400/files/0742.pdf$$yOriginal version of the author's contribution in proceedings, page 742, section KIN.
000021400 962__ $$r21225
000021400 980__ $$aPAPER