000022769 520__ $$2eng$$aThe measurements of flow rates of fluids are some of the most common procedures applied in practice. Beside the standard examples of flow measurements, we often have to do with complex issues that occur in the relatively long sections of a straight pipeline. Such issues need to an individual approach to be taken. In such cases, it is useful to apply a mathematical flow modeling of a given flow system. The present paper presents two examples of such problems. These problems focus on an installation that is applied for feeding air into a coal mill. The results of the mathematical flow modeling of an installation provided a manner in which the location of a flowmeter can be established. Such a location provides a decrease of the measurement uncertainty as well as provides a manner in which the reliability of the flow system can be improved.

000022769 540__ $$aText je chráněný podle autorského zákona č. 121/2000 Sb.
000022769 653__ $$aaveraging Pitot tubes, flowmeter, CFD, measurement uncertainty

000022769 7112_ $$aEngineering Mechanics 2018$$cSvratka, CZ$$d2018-05-14 / 2018-05-17$$gEM2018
000022769 720__ $$aKabaciński, M.$$iPochwała, S.$$iPospolita, J.$$iKrogulec, D.
000022769 8560_ $$ffischerc@itam.cas.cz
000022769 8564_ $$s768327$$uhttps://invenio.itam.cas.cz/record/22769/files/345.pdf$$yOriginal version of the author's contribution in proceedings, page , section FLU.
000022769 962__ $$r21225
000022769 980__ $$aPAPER