000022848 001__ 22848
000022848 005__ 20220110134530.0
000022848 04107 $$aeng
000022848 046__ $$k2018-05-14
000022848 100__ $$aPečínka, L.
000022848 24500 $$aEffect of the pulsations generated by the main circulation pumps on the measurement of the coolant flow in the VVER 1000/320 reactor

000022848 24630 $$n24.$$pEngineering Mechanics 2018
000022848 260__ $$bInstitute of Theoretical and Applied Mechanics of the Cech Academy of Sciences, Prague
000022848 506__ $$arestricted
000022848 520__ $$2eng$$aMeasurement of the coolant flow in the primary circuit of the VVER 1000/320 reactor is based on the measurement of the pressure drop either on the main circulation pump, or reactor or steam generator. It will be proved that the existence of the pressure pulsations result in differences between the rate indicated by the flow meters and the actual flow rate.

000022848 540__ $$aText je chráněný podle autorského zákona č. 121/2000 Sb.
000022848 653__ $$apressure pulsations, sine wave, binomial theorem, trinomial expansion, frequency changes.

000022848 7112_ $$aEngineering Mechanics 2018$$cSvratka, CZ$$d2018-05-14 / 2018-05-17$$gEM2018
000022848 720__ $$aPečínka, L.$$iKrupa, Vl.
000022848 8560_ $$ffischerc@itam.cas.cz
000022848 8564_ $$s279134$$uhttps://invenio.itam.cas.cz/record/22848/files/661.pdf$$yOriginal version of the author's contribution in proceedings, page , section DYN.
000022848 962__ $$r21225
000022848 980__ $$aPAPER