A comparison of multiple step and single step methods for determining cyclic stress-strain relationship for two non-masing materials


Abstract eng:
Two ferritic-pearlitic steel grades were tested using single and multiple step methods of determination of cyclic stress-strain relationship. Both materials exhibit a change from Masing to nonMasing hysteretic behavior at some strain level, when subjected to multiple step method. In case of single step method only non-Masing behavior was observed. Despite that, it was shown that using the multiple step method, which is less accurate than single step one, can give very satisfactory results. The stress-strain curves were described using the master curve method, since the commonly used Ramberg-Osgood equation cannot be used for non-Masing materials.

Publisher:
Institute of Theoretical and Applied Mechanics of the Cech Academy of Sciences, Prague
Conference Title:
Conference Title:
Engineering Mechanics 2018
Conference Venue:
Svratka, CZ
Conference Dates:
2018-05-14 / 2018-05-17
Rights:
Text je chráněný podle autorského zákona č. 121/2000 Sb.



Record appears in:



 Record created 2022-01-10, last modified 2022-01-10


Original version of the author's contribution in proceedings, page , section FRA.:
Download fulltext
PDF

Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)