000003295 001__ 3295
000003295 005__ 20141118153404.0
000003295 04107 $$acze
000003295 046__ $$k2005-05-09
000003295 100__ $$aJirouš, F.
000003295 24500 $$aSteam flow distribution in the separator of VVER 440

000003295 24630 $$n11.$$pENGINEERING MECHANICS 2005
000003295 260__ $$bInstitute of Thermomechanics AS CR, v.v.i., Brno
000003295 506__ $$arestricted
000003295 520__ $$2eng$$aThe reactors VVER – 440 are cooled and moderated by pressurized water – PWR. The primary coolant is subcooled in the PWR and steam is generated by transferring energy from the primary system to a lower pressure fluid in the steam generator. Steam flow from the generator reaches the high pressure turbine . After expansion in the high pressure turbine, the steam passes through a moisture separator, which is a low pressure drop separator external to the turbine. After passing through this separator, the steam is reheated before entering the low pressure turbine. Separator surfaces can suffer erosion– corrosion. Erosion rate is a function of velocity and of moisture stream. The paper deals with the influence of separator head design on flow distribution in the separator system.

000003295 540__ $$aText je chráněný podle autorského zákona č. 121/2000 Sb.
000003295 653__ $$a

000003295 7112_ $$aENGINEERING MECHANICS 2005$$cSvratka (CZ)$$d2005-05-09 / 2005-05-12$$gEM2005
000003295 720__ $$aJirouš, F.$$iHärtel, P.
000003295 8560_ $$ffischerc@itam.cas.cz
000003295 8564_ $$s2683383$$uhttps://invenio.itam.cas.cz/record/3295/files/Jirous-PT.pdf$$y
             Original version of the author's contribution as presented on CD, .
            
000003295 962__ $$r3238
000003295 980__ $$aPAPER