000003526 24500 $$aComparison of heat transfer in a straight and helical tube and influence of preset singularities on heat transfer in a straight tube at the flow of surfactant solutions

000003526 24630 $$n12.$$pENGINEERING MECHANICS 2006
000003526 260__ $$bInstitute of Theoretical and Applied Mechanics, AS CR, v.v.i., Prague
000003526 506__ $$arestricted
000003526 520__ $$2eng$$aExperiments were made on a hydraulic facility with closed loop. The influence of a preset valve and circular bend 180° on the heat transfer along the 16 mm tube was investigated. Three different concentrations of cationic surfactant Arquad S 50 (oleyltrimethylammonium chloride) in mixture with NaSal (sodium salicylate) were experimented with. The range of Reynolds numbers was 8.000100.000 and the heat flux through the tube wall was 22 and 40 kW/m2.