000003932 001__ 3932
000003932 005__ 20141118153341.0
000003932 04107 $$acze
000003932 046__ $$k2009-05-11
000003932 100__ $$aKytýř, D.
000003932 24500 $$aMicrostructural properties of acetabular region of human pelvic bone revealed using micro-CT

000003932 24630 $$n15.$$pEngineering Mechanics 2009
000003932 260__ $$bInstitute of Theoretical and Applied Mechanics AS CR, v.v.i., Prague
000003932 506__ $$arestricted
000003932 520__ $$2eng$$aThe paper deals with microstructure investigation of trabecular bone in acetabular region. Trabecular bone microstructure is the main factor of the bone quality and mechanical propertites at macroscopic level. Data from high resolution micro Computed Tomography can be used to reconstruct the complex geometry of the trabecular bone inner structure and interface between bone and implant. The data are usable as for micro-FE modeling as well as for experimental loading tests evaluation.

000003932 540__ $$aText je chráněný podle autorského zákona č. 121/2000 Sb.
000003932 653__ $$a

000003932 7112_ $$aEngineering Mechanics 2009$$cSvratka (CZ)$$d2009-05-11 / 2009-05-14$$gEM2009
000003932 720__ $$aKytýř, D.$$iVavřík, D.$$iJiroušek, O.
000003932 8560_ $$ffischerc@itam.cas.cz
000003932 8564_ $$s2593972$$uhttps://invenio.itam.cas.cz/record/3932/files/Kytyr-273-PT.pdf$$y
             Original version of the author's contribution as presented on CD, 273.
            
000003932 962__ $$r3852
000003932 980__ $$aPAPER