BIOMECHANICS OF SPINE UNDER CORRECTION BRACE EFFECTS


Abstract cze:
Abstrakt: The topic of this paper is a computer simulation of treatment of children spine deformities with braces (orthosis). Orthopaedists in the Czech Republic use corrective braces of type Cheneau or Cerny. The brace has force effects on a child skeleton. First, the negative plaster form of a child trunk is made and then the positive plaster form is created. The orthopaedist determines the loading place and the plaster form is deepened in this place. The laminate brace made according to this plaster form pushes the child trunk (like a tight shoe). The research is supported by a grant of the Czech Grant Agency No. 10610010006 "Functional Adaptation and Pathobiomechanics of Limb and Axial Skeleton under Force Effects ". The paper shows the manner of determination of the stress state in vertebrae and inter-vertebra discs and the solution of the spinal curve correction under brace force effects for a concrete child patient. The project searches the dependence of the activation and velocity of the spinal curve correction in the spinal stress state for many patients. It means that the paper shows the computing algorithms for spinal deformations and the stress state under brace force effects and the simulation of the spinal curve correction. Louis's model of the spine is used. The breast curve classification can be used according to King. Note that the brace of type Chenau is recommended for the spinal curve type King I, I/, and IV and the brace of type Cerny for the spinal curve of type King I/, III a V The spinal deformations are solved by the finite element method as a beam (spine) in an elastic ground (soft tissue) loaded by given displacements or by the finite element method using vertebrae, inter-vertebra discs and soft tissue elements. The Ft method is described in the article. The calculation algorithm and parameters are verified with treatment courses. The sensor plates put into braces have measured the load values between the brace and the child trunk surface. The simulation program assesses the spinal curve correction according to the spinal stress state and the time for which the brace has been used.

Abstract eng:
Abstract: The topic of this paper is a computer simulation of treatment of children spine deformities with braces (orthosis). Orthopaedists in the Czech Republic use corrective braces of type Cheneau or Cerny. The brace has force effects on a child skeleton. First, the negative plaster form of a child trunk is made and then the positive plaster form is created. The orthopaedist determines the loading place and the plaster form is deepened in this place. The laminate brace made according to this plaster form pushes the child trunk (like a tight shoe). The research is supported by a grant of the Czech Grant Agency No. 10610010006 "Functional Adaptation and Pathobiomechanics of Limb and Axial Skeleton under Force Effects ". The paper shows the manner of determination of the stress state in vertebrae and inter-vertebra discs and the solution of the spinal curve correction under brace force effects for a concrete child patient. The project searches the dependence of the activation and velocity of the spinal curve correction in the spinal stress state for many patients. It means that the paper shows the computing algorithms for spinal deformations and the stress state under brace force effects and the simulation of the spinal curve correction. Louis's model of the spine is used. The breast curve classification can be used according to King. Note that the brace of type Chenau is recommended for the spinal curve type King I, I/, and IV and the brace of type Cerny for the spinal curve of type King I/, III a V The spinal deformations are solved by the finite element method as a beam (spine) in an elastic ground (soft tissue) loaded by given displacements or by the finite element method using vertebrae, inter-vertebra discs and soft tissue elements. The Ft method is described in the article. The calculation algorithm and parameters are verified with treatment courses. The sensor plates put into braces have measured the load values between the brace and the child trunk surface. The simulation program assesses the spinal curve correction according to the spinal stress state and the time for which the brace has been used.

Publisher:
Institute of Mechanics and Solids, FME, TU Brno
Conference Title:
Conference Title:
Engineering Mechanics 2002
Conference Venue:
Svratka (CZ)
Conference Dates:
2002-05-13 / 2002-05-16
Rights:
Text je chráněný podle autorského zákona č. 121/2000 Sb.



Record appears in:

 Record created 2014-10-23, last modified 2014-11-18


Original version of the author's contribution as presented on CD, . :
Download fulltext
PDF

Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)