000009261 24500 $$aResistance of concrete with fly ash content under the RWS curve fire loading

000009261 24630 $$n18.$$pEngineering Mechanics 2012
000009261 260__ $$bInstitute of Theoretical and Applied Mechanics, AS CR, Prague
000009261 506__ $$arestricted
000009261 520__ $$2eng$$aThe first part of the paper presents the results obtained from large scale fire experiments on reinforced concrete panels 1.5 x 3.0 meters and small scale high temperature experiments on cubes with a side length equal to 0.15 meters. Concrete mixtures with large content of fly ash as a bi nder were selected for large scale exp eriments whereas cubes were made of cement based mixtures as w ell as of alkali activated fly ash mixtures. The influence on polypropylene fibres, added into half of the specimens, on the fire resistance is also described. Second part of the paper is focused on the numerical modelling of the effect of fire using a simplified numerical approach. Experimental data are used for calibration of the models as well as for the comparison of results. The loading is governed by RWS Curve which assumes 50 cubic meters of petrol or oil fire in the tunnel.

000009261 540__ $$aText je chráněný podle autorského zákona č. 121/2000 Sb.
000009261 653__ $$afire resistance, heat transfer, spalling, fly ash, PP fibres

000009261 7112_ $$aEngineering Mechanics 2012$$cSvratka (CZ)$$d12/05/2014 - 15/05/2014$$gEM2012
000009261 720__ $$aŠejnoha, M.$$iBrouček, M.$$iNovotná, E.$$iSýkora, J.
000009261 8560_ $$ffischerc@itam.cas.cz
000009261 8564_ $$s1676280$$uhttps://invenio.itam.cas.cz/record/9261/files/232_Broucek_M-FT.pdf$$yOriginal version of the author's contribution as presented on CD, paper (No. 232).
000009261 962__ $$r8924
000009261 980__ $$aPAPER