000009881 001__ 9881
000009881 005__ 20141205153203.0
000009881 04107 $$aeng
000009881 046__ $$k2008-10-12
000009881 100__ $$aDiotallevi, Pier Paolo
000009881 24500 $$aSeismic Assessment of an Existing RC Hospital Building: Study for the Rehabilitation with Supplemental Fluid-Viscous Dampers

000009881 24630 $$n14.$$pProceedings of the 14th World Conference on Earthquake Engineering
000009881 260__ $$b
000009881 506__ $$arestricted
000009881 520__ $$2eng$$aThis paper describes a study for the seismic assessment and rehabilitation of an existing RC hospital building using fluid-viscous dampers. The structure, located in Italy, was built in the earlier 70s and it was designed without considering the seismic action. Due to a change in the seismic classification of the territory, the location is now classified as a seismic zone. The building is characterized by eight storey and by an asymmetric “T” shaped plan. The lateral resisting system is made of frames and shear walls in correspondence to stairs and elevators. This structure was analyzed by developing a non-linear model and by applying pushover procedures. The assessment was carried out in the framework of multi-level performance based approach. The adopted retrofit strategy is based on

000009881 540__ $$aText je chráněný podle autorského zákona č. 121/2000 Sb.
000009881 653__ $$aRC Structures, Pushover Analysis, Seismic Assessment, Existing Buildings, Seismic Rehabilitation, Fluid-Viscous Damper

000009881 7112_ $$a14th World Conference on Earthquake Engineering$$cBejing (CN)$$d2008-10-12 / 2008-10-17$$gWCEE15
000009881 720__ $$aDiotallevi, Pier Paolo$$iLandi, Luca$$iBusca, Alessandro
000009881 8560_ $$ffischerc@itam.cas.cz
000009881 8564_ $$s214505$$uhttps://invenio.itam.cas.cz/record/9881/files/11-0151.pdf$$yOriginal version of the author's contribution as presented on CD, Paper ID: 11-0151.
000009881 962__ $$r9324
000009881 980__ $$aPAPER