The Institute of Theoretical and Applied Mechanics 25 records found  1 - 10nextend  jump to record: Search took 0.01 seconds. 
1.
Reinforced Concrete structures are designed to satisfy requirements regarding safety, serviceability and durability throughout their design service life. The present pape [...]
2.
In the nineteenth century, Marseille was already an established industrial town and had a significant urban development. Its business provided it with a large amount of r [...]
3.
Leschnik, W.
This paper deals with the sound protection of half-timbered buildings. It shall help architects and engineers to consider the sound insulation when planning such building [...]
4.
This contribution deals with deriving the effective matrices of the linear-elastic composite multilayered sandwich beam finite element with a constant cross-section (whic [...]
5.
This paper is devoted to a FEM numerical simulation of bond-slip behavior between epoxy coated plain steel bars and concrete. In this case the cured epoxy coating is assu [...]
6.
The paper presents experimental determination of mechanical properties of different types of animal hairs. Mortars reinforced by thin fibres have promising properties for [...]
7.
This paper describes the nonlinear analysis of the reinforced concrete wall of the bubbler tower (BT) due to extreme pressure and temperature loading. The behaviour of th [...]
8.
Karczmarzyk, S.
An exact local model for computing the coincidence frequencies of multilayered sandwich panels and numerical results predicted by the model are presented in the paper. Th [...]
9.
This paper presents an experimental investigation on mechanical properties and durability of fibre reinforced concrete (FRC) incorporating polypropylene (PP) fibres expos [...]
10.
The contribution deals with the straight sandwich bar element derived by new nonincremental full geometric nonlinear approach. We assume a twonode straight sandwich compo [...]
11.
Blood – aortic wall interaction was investigated in a current work using the uncoupled method. The method is based on alternating, relatively independent solutions of t [...]
12.
The corrosion caused by the action of chloride ions represents the greatest threat to the durability and service life of reinforced concrete structures. This pathological [...]
13.
The solution of vibration transfer from the subsoil to the structure is demonstrated using the example of a multi-storey reinforced concrete building, founded on a dual f [...]
14.
Fiber Reinforced Concrete (FRC) can improve not only mechanical properties but also durability due to reduced crack width by fiber bridging effect. From the view point of [...]
15.
Kowolik, B.
Due to its numerous advantages steel it generally applied in the design of building structures. It displays, however, two fundamental drawbacks, viz. it is susceptible to [...]
16.
This paper examines the influence of reinforcement steel elemental composition and surface condition (polished and unpolished) on the corrosion rate of reinforced concret [...]
17.
The paper deals with the study of dominant frequencies of an Impact-Echo method response signal obtained from a reinforced concrete beam with a steel rod diameter of 6mm. [...]
18.
We present the orthotropic hyperelastic material model for numerical simulation of the loading of the cylindrical membrane. The coefficients of strain energy function of [...]
19.
Corrosion of reinforcing steel in concrete is one of the most influencing factors causing the degradation of reinforced concrete structures, conducting to concrete crack [...]
20.
Sandwich construction elements, i.e. elements formed by two skins and core, excel in high ratio of bending stiffness to weight of construction. This complex is designed i [...]
21.
This paper presents a water hammer experiment performed on an physical model of blood vessel. Physical model of blood vessel was manufactured from latex tubes textile rub [...]
22.
In the present paper a parametric study is conducted based on an existing finite element based model. The influence of cover layer, reinforcement diameter and water-to-ce [...]
23.
24.
A two-layer statistically equivalent periodic unit cell with air voids is offered to predict a macroscopic response of plain weave multilayer textile composites. Two diff [...]
25.
The main reason for the thickness of a concrete sandwich element is the requirement for the protective concrete cover for the steel reinforcement. Use of textile reinforc [...]

Haven't found what you were looking for? Try your search on other servers:
recid:2209 in Amazon
recid:2209 in CERN EDMS
recid:2209 in CERN Indico
recid:2209 in CERN Intranet
recid:2209 in CiteSeer
recid:2209 in Google Books
recid:2209 in Google Scholar
recid:2209 in Google Web
recid:2209 in IEC
recid:2209 in IHS
recid:2209 in INSPEC
recid:2209 in INSPIRE
recid:2209 in ISO
recid:2209 in KISS Books/Journals
recid:2209 in KISS Preprints
recid:2209 in NEBIS
recid:2209 in SLAC Library Catalog