Non-Structural Component Performance in 4-Story Frame Tested to Collapse


Abstract eng:
In the shake table test conducted on a full-scale 4 story steel building at the E-Defense three-dimensional shake table facility, various non-structural components were installed to the specimen to evaluate their seismic performance. These components are ALC (autoclaved lightweight concrete) external wall cladding panels, aluminum sash, glass window, gypsum board partition walls, hanging ceiling system, and so on. Generally, non-structure components are designed to remain undamaged up to a story drift of 0.005 ~ 0.01 rad. On the other hand, by the shaking table test at the E-Defense, the 1st story was collapsed and the maximum story drift angle over 2nd story was reached to nearly 0.02 rad. So, we can observe the damage and evaluate the seismic performance for the drift angle of design level to more over.