Shear Behavior of Multi-Story RC Structural Walls with Eccentric Openings


Abstract eng:
Static loading test was conducted on four 40%-scale specimens in order to evaluate the shear transfer mechanisms of structural walls with eccentric openings. Specimen configuration was determined from a typical six-story building in Japan. The experimental variables were the size and location of openings. From experimental results, shear strength of specimens were estimated using the existing codes and reduction factors. It was shown that the shear strengths of specimens were estimated combining the shear strength of structural walls without openings and Ono’s reduction factor. The employed computing method well simulated the test results. It was proved that the method may be applied to structural walls with the opening ratio less than 0.46. Then a two-dimensional FEM analytical model was constructed to simulate the behavior observed in the experiment. The model well simulated lateral load – drift angle relations and damage distribution of wall panels.

Contributors:
Conference Title:
Conference Title:
14th World Conference on Earthquake Engineering
Conference Venue:
Bejing (CN)
Conference Dates:
2008-10-12 / 2008-10-17
Rights:
Text je chráněný podle autorského zákona č. 121/2000 Sb.



Record appears in:



 Record created 2014-12-05, last modified 2014-12-05


Original version of the author's contribution as presented on CD, Paper ID: S15-029.:
Download fulltext
PDF

Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)