Numerical Simulation of the Dynamic and Earthquake Behaviour of Greek Post-Byzantine Churches with and Without Base Isolation


Abstract eng:
The dynamic and earthquake response of Post-Byzantine stone masonry churches, which were subjected to a damaging earthquake sequence in the region of Western Macedonia in Greece, is studied. Two structural systems of the “basilica” form are first examined. Apart from these two “basilica” churches, the behavior of another much older church, which represents a much simpler orthogonal structural formation, is also examined. This is a twostory church with a simple orthogonal vault and a wooden roof that belongs to an 11th century monastic-complex. Two of these churches are also studied together with the introduction of a base isolation system. The performance of each of these three distinct structures is studied under the combination of the gravitational and seismic forces. The predicted performance of the various structural elements, located at the peripheral masonry walls is then checked by applying an assumed Mohr-Coulomb failure envelope that is believed to represent the limitstate stone-masonry behavior. The seismic damage, due to a relatively recent strong earthquake sequence, is utilized to validate the realism of the numerical predictions. The numerical introduction of a base-isolation system was quite effective in lowering the demands and thus resulting for most structural elements in Capacity/Demand ratio values larger than one (Capacity/Demand > 1), which is assumed to indicate acceptable structural performance. However, the introduction of base isolation under an existing old stone-masonry structure is also faced with considerable difficulties, despite the advantages that are shown by the results of numerical investigation. In the particular case of “The Church of The Virgin Mary of Tourniki” these difficulties must be faced because this old church has to be moved in a different location due to flooding. Thus, the placement of a base isolation scheme under this structure in its new location is a feasible solution for this particular case with no significant extra cost. Obviously, thus base isolation scheme should be considered in addition to all other traditional repair and strengthening measures for this church.

Contributors:
Publisher:
National Technical University of Athens, 2011
Conference Title:
Conference Title:
COMPDYN 2011 - 3rd International Thematic Conference
Conference Venue:
Island of Corfu (GR)
Conference Dates:
2011-05-25 / 2011-05-28
Rights:
Text je chráněný podle autorského zákona č. 121/2000 Sb.



Record appears in:



 Record created 2016-11-14, last modified 2016-11-14


Original version of the author's contribution as presented on CD, section: MS 14 Innovative vs. Conventional Retrofitting of Existing Buildings.:
Download fulltext
PDF

Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)