A paramedic study of the effect of a tornado generator’s geometric design on the flow field


Abstract eng:
Surface pressure and velocity flow field data have been measured in a tornado simulator for a constant aspect ratio and for two different swirl ratios. An investigation has been undertaken in order to establish what, if any, effect the convection chamber height has on the results. The tentative results suggest that the height of the convection chamber can influence the flow field. This is a potentially important finding and thus has implications for the physical simulation of tornado-type flows.

Contributors:
Publisher:
l'Association pour l'Ingénierie du Vent
Conference Title:
Conference Title:
7th European and African Conference on Wind Engineering
Conference Venue:
Liège, BE
Conference Dates:
2017-07-04 / 2017-07-07
Rights:
Text je chráněný podle autorského zákona č. 121/2000 Sb.



Record appears in:



 Record created 2017-07-24, last modified 2017-07-24


Original version of the author's contribution in proceedings, id 3, section .:
Download fulltext
PDF