Effect of the pulsations generated by the main circulation pumps on the measurement of the coolant flow in the VVER 1000/320 reactor


Abstract eng:
Measurement of the coolant flow in the primary circuit of the VVER 1000/320 reactor is based on the measurement of the pressure drop either on the main circulation pump, or reactor or steam generator. It will be proved that the existence of the pressure pulsations result in differences between the rate indicated by the flow meters and the actual flow rate.