Resistance of concrete with fly ash content under the RWS curve fire loading


Abstract eng:
The first part of the paper presents the results obtained from large scale fire experiments on reinforced concrete panels 1.5 x 3.0 meters and small scale high temperature experiments on cubes with a side length equal to 0.15 meters. Concrete mixtures with large content of fly ash as a bi nder were selected for large scale exp eriments whereas cubes were made of cement based mixtures as w ell as of alkali activated fly ash mixtures. The influence on polypropylene fibres, added into half of the specimens, on the fire resistance is also described. Second part of the paper is focused on the numerical modelling of the effect of fire using a simplified numerical approach. Experimental data are used for calibration of the models as well as for the comparison of results. The loading is governed by RWS Curve which assumes 50 cubic meters of petrol or oil fire in the tunnel.

Contributors:
Publisher:
Institute of Theoretical and Applied Mechanics, AS CR, Prague
Conference Title:
Conference Title:
Engineering Mechanics 2012
Conference Venue:
Svratka (CZ)
Conference Dates:
12/05/2014 - 15/05/2014
Rights:
Text je chráněný podle autorského zákona č. 121/2000 Sb.



Record appears in:



 Record created 2014-12-04, last modified 2014-12-04


Original version of the author's contribution as presented on CD, paper (No. 232).:
Download fulltext