Experimental Behavior of Single and Double Masonry Panels


Abstract eng:
In this paper, the results of the experimental tests, carried out at the Laboratory on Materials and Structures of the University of Roma Tre to characterize masonry panels behavior are shown and discussed. 36 single and 12 double panels have been considered: 12 single panels are made of 80×160×330 mm3 bricks with horizontal holes, 24 of 120×250×120 mm3 half-full bricks with vertical holes and two different mortars and 12 double panels coupling the two previous types of simple panels. The panels have been built with a level of accuracy similar to the one adopted in buildings therefore they are well done but not lacking some defects that unavoidably would be found in real constructive practice. Compression tests in horizontal, vertical and diagonal directions were performed to evaluate their “constitutive relationships” in term of force-displacement diagrams and in particular their strength and elastic modulus. Experimental tests also included the characterization of the bricks and of the mortar used to realize the panels.

Contributors:
Conference Title:
Conference Title:
14th World Conference on Earthquake Engineering
Conference Venue:
Bejing (CN)
Conference Dates:
2008-10-12 / 2008-10-17
Rights:
Text je chráněný podle autorského zákona č. 121/2000 Sb.



Record appears in:



 Record created 2014-12-05, last modified 2014-12-05


Original version of the author's contribution as presented on CD, Paper ID: 12-01-0174.:
Download fulltext
PDF

Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)