Strengthening of Historic Reinforced Brick Wall Building Implemented with Energy Dissipation Devices


Abstract eng:
This research compared with the seismic response analysis of two stories historic reinforced brick wall building stand up Di-Hwa street of famous historic area in the north of Taipei city, which implemented or not implemented with energy dissipation devices (fluid viscous damper-FVD). The analysis results shows a two stories historic reinforced brick wall building set to two rigid plate is more reasonable, structural strengthening by implemented with FVD is much better than the other structural strengthening method, for structural seismic resistant design, the earthquake induced building horizontal shear force decrease in 87.8 %; the response of acceleration decrease in 90.7%; the response of floor displacement decrease in 93.22%; The response of story drifts decrease in 91.4% in the minimum requirement of building base shear force under seismic resistant design code of Taiwan.

Contributors:
Conference Title:
Conference Title:
14th World Conference on Earthquake Engineering
Conference Venue:
Bejing (CN)
Conference Dates:
2008-10-12 / 2008-10-17
Rights:
Text je chráněný podle autorského zákona č. 121/2000 Sb.



Record appears in:



 Record created 2014-12-05, last modified 2014-12-05


Original version of the author's contribution as presented on CD, Paper ID: S11-095.:
Download fulltext
PDF

Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)