1.
|
This paper deals with pore size distribution assessment in trabecular structure of human proximal femur. Two different approaches for estimation of histograms of pore siz [...]
|
2.
|
Abstrakt: The paper deals with the bone tissue modelling as a micropolar continuum. Isotropic and orthotropic constitutive relations were used for the description of the [...]
|
3.
|
Two parameters of bone microarchitecture: volume of bone layer and fractal dimension were used. 42 human bone samples were cut to cylindrical testing samples of 8.5 mm th [...]
|
4.
|
The contribution presents experimental investigation of the frequency modal, damping and stress wave propagation characteristics and finite element (FE) mode ling of the [...]
|
5.
|
This work is founded on the co-operation of Czech Technical University in Prague, Faculty of Mechanical Engineering, Laboratory of Biomechanics of Man and the First Facul [...]
|
6.
|
The paper discusses an alternative approach to a trabecular bone modelling. The proposed method is based on simple models that are created from finite elements with diffe [...]
|
7.
|
In the article a detailed comparison of techniques used to develop detailed FE models of trabecular bone microstructure is presented. The FE models are built using a stac [...]
|
8.
|
The aim of the study was to present influence of the three-dimensional spacing of the bone implants to the stability of bone fracture fixing in biplane external stabilize [...]
|
9.
|
This paper deals with investigation of contact pressure development in contact area between titanium cervical implant (Tibon) and cervical vertebrae. Material of bone tis [...]
|
10.
|
This paper belongs to biomechanics of a hip joint section. It is engaged in problems with industrial tolerances for dimensions as one of the possible total hip prosthesis [...]
|
11.
|
This article deals with the stress analysis of the Burch-Schneider (BS) cage as applied to a hip joint. Due to the complex geometry of the solved problem, material proper [...]
|
12.
|
In general all orthopaedic operations may cause the change of muscle balance. This unbalance various not only range of movement but also the loading vector during the mov [...]
|
13.
|
The article deals with contact stress analysis of pelvic bone after implantation of cemented acetabular component with imperfections of cemented layer. 3D high resolution [...]
|
14.
|
The article deals with development and validation of complex FE model of pelvic bone and acetabular component. The model of pelvic bone is constructed on basis of CT data [...]
|
15.
|
The paper deals with loosening and migration of acetabular cup into the pelvis that belongs to the most serious therapeutic complications arising sometimes several months [...]
|