guest ::
login
The Institute of Theoretical and Applied Mechanics
Search
Submit
Personalize
Your alerts
Your baskets
Your searches
Help
Home
> Search Results: recid:1959
Search:
any field
abstract
affiliation
author
author count
authority author
authority institute
authority journal
authority subject
caption
cataloguer nickname
cited by
cited by excluding self cites
coden
collaboration
collection
date created
date modified
division
doi
exact author
exact first author
exact title
experiment
file type
first author
fulltext
isbn
issn
item count
journal
keyword
miscellaneous
record ID
reference
reference to
refers to
refers to excluding self cites
report number
restriction
subject
title
year
Search Tips
::
Advanced Search
Search collections:
*** any public collection ***
Administrative Reports
Author Works
Author Works for Approval
ITAM Library
Company Publications
Company Publications for Appro...
Conference Contributions
Conference Materials
Conference Materials for Appro...
Conference Proceedings
Conference Programs
eBooks
Essays
Exam Topics
Lecture Notes
Monographs
Papers
Posters
Preprints
Presentations
Proceedings
Product Instructions
Production Catalogues
Project Documents
Reports
Reports for Approval
Research Reports
Sillabi
Study materials
Study Materials for Approval
The Institute of Theoretical a...
Theses
Theses for Approval
Sort by:
Display results:
Output format:
latest first
title
author
report number
year
asc.
desc.
- or rank by -
word similarity
times cited
selfcites
10 results
25 results
50 results
100 results
single list
split by collection
BibTeX
Dublin Core
EndNote
EndNote (8-X)
HTML brief
HTML citesummary
HTML detailed
MARC
MARCXML
MODS
NLM
photo captions only
portfolio
RefWorks
Untitled
The Institute of Theoretical and Applied Mechanics
20
records found 1 - 10
jump to record:
Search took 0.02 seconds.
1.
(75)
Original version of the author's contribution as presented on CD, . :
PDF
PARAMETRIC DESCRIPTION OF THE DEVELOPMENT OF SECANT MODULUS OF ELASTICITY OF CONCRETE UNDER CYCLIC LOADING
Foglar, M.
;
Štemberk, P.
Fatigue is a process of permanent progressive changes in the structure of a material exposed to cyclic loading. This paper describes the strain development in concrete st [...]
Detailed record
-
Similar records
2.
(75)
Original version of the author's contribution as presented on CD, . :
PDF
POSSIBILITIES OF CONTROL EXPERIMENTAL TESTING DEVICES FOR BIOMECHANICS
Houška, P.
;
Ondroušek, V.
This paper describes our approach to control of the two types of experimental devices for biomechanics. First type of experimental device is the device for examining the [...]
Detailed record
-
Similar records
3.
(75)
Original version of the author's contribution as presented on CD, . :
PDF
Mechanical analysis of contact between ball head and acetabular fossa of total hip prosthesis
Koukal, M.
;
Florian, Z.
This paper belongs to biomechanics of a hip joint section. It is engaged in problems with industrial tolerances for dimensions as one of the possible total hip prosthesis [...]
Detailed record
-
Similar records
4.
(75)
Original version of the author's contribution as presented on CD, . :
PDF
The compatibility of earth-based repair mortars with rammed earth substrates
Gomes, M. I.
;
Faria, P.
Earth constructions are susceptible to degradation due to natural or human causes. The degradation of the exterior surface of earth walls is very common, either due to la [...]
Detailed record
-
Similar records
5.
(76)
Original version of the author's contribution as presented on CD, , page 177. :
PDF
Macroscopic modeling of electro-osmosis in the porous structure of a cortical bone tissue
Turjanicová, J.
;
Rohan, E.
Detailed record
-
Similar records
6.
(76)
Original version of the author's contribution as presented on CD, . :
PDF
Investigation of contact pressure development in the system cervical implant – bone
Klement, M.
;
Hruš, T.
This paper deals with investigation of contact pressure development in contact area between titanium cervical implant (Tibon) and cervical vertebrae. Material of bone tis [...]
Detailed record
-
Similar records
7.
(76)
Original version of the author's contribution as presented on book, page 155. :
PDF
PROBABILITY OF DESTRUCTIONS OF CERAMICS USING WEIBULL'S THEORY
Fuis, V.
;
Janíček, P.
The probability calculation using two variants of Weibull weakest-link theory is presented in this article. The first varian assumed only one tensile stress (the first pr [...]
Detailed record
-
Similar records
8.
(76)
Original version of the author's contribution as presented on CD, . :
PDF
BONE TISSUE MODELLING BASED ON THE ORTHOTROPIC MICROPOLAR CONTINUUM
Rosenberg, Josef
;
Nováček, Vit
Abstrakt: The paper deals with the bone tissue modelling as a micropolar continuum. Isotropic and orthotropic constitutive relations were used for the description of the [...]
Detailed record
-
Similar records
9.
(77)
Original version of the author's contribution as presented on CD, BIO. :
PDF
Modelling and simulation of mechanical parameters of bone fracture slot using external fixation
Jasińska-Choromańska, D.
;
Sadzyński, I.
Long bone fractures can be healed using external fixators - devices that stiffly fix fracture fragments using parallel to the bone, attached with pins frame. This method [...]
Detailed record
-
Similar records
10.
(77)
Original version of the author's contribution as presented on CD, . :
PDF
FINITE ELEMENT RECONSTRUCTION OF CRANIOCEREBRAL INJURY
Jiroušek, O.
;
Jírová, J.
The paper deals with reconstruction of a sport accident using detailed FE model of skull and brain is presented in the paper. The sport accident involved a 12-year old bo [...]
Detailed record
-
Similar records
11.
(79)
Original version of the author's contribution as presented on CD, POS. :
PDF
Influence of the measured contact cone shape deflections of the hip joint endoprosthesis on the stress and reliability values
Fuis, V.
;
Hlavoň, P.
The paper presents the results of the computational modelling of the stress states in the ceramic head of the hip joint endoprosthesis. The analysed system is loaded acco [...]
Detailed record
-
Similar records
12.
(80)
Original version of the author's contribution as presented on CD, . :
PDF
MUSCLE UNBALANCE INFLUENCE TO HIP IMPLANT MIGRATION
Kytýř, D.
;
Jíra, J.
In general all orthopaedic operations may cause the change of muscle balance. This unbalance various not only range of movement but also the loading vector during the mov [...]
Detailed record
-
Similar records
13.
(81)
Original version of the author's contribution as presented on CD, . :
PDF
Manufacturing accuracy versus reliability of the hip joint endoprosthesis ceramic head
Fuis, V.
The paper deals with the problems of the stress and failure probability of the ceramic head of hip joint endoprosthesis. Computational modeling is used to solve the probl [...]
Detailed record
-
Similar records
14.
(81)
Stress and reliability analyses of hip joint endoprosthesisi ceramic head under oblique loading
Fuis, V.
;
Ochranová, M.
Abstrakt:
Detailed record
-
Similar records
15.
(83)
Original version of the author's contribution as presented on CD, BIO. :
PDF
Development of testing equipment for measuring mechanical properties of cancellous bone
Jiroušek, O.
;
Vavřík, D.
The article reports on development of experimental procedures used for evaluation of mechanical properties of cancellous bone using small samples of cylindrical shape. Bo [...]
Detailed record
-
Similar records
16.
(83)
Original version of the author's contribution as presented on book, page 379. :
PDF
CREATION OF COMPUTATIONAL MODELS OF CANCELLOUS BONE
Marcián, P.
;
Navrátil, P.
The paper deals with a creation of computational model of cancellous bone. Cancellous bone is inner porous part of bones and it is of a very complex geometry. It is compo [...]
Detailed record
-
Similar records
17.
(83)
Original version of the author's contribution as presented on CD, . :
PDF
Interaction of pelvic bone and acetabular component
Vyčichl, J.
;
Jiroušek, O.
The article deals with development and validation of complex FE model of pelvic bone and acetabular component. The model of pelvic bone is constructed on basis of CT data [...]
Detailed record
-
Similar records
18.
(84)
Original version of the author's contribution as presented on CD, . :
PDF
INTERACTION BETWEEN PELVIC BONE AND ACETABULAR COMPONENT WITH NON-UNIFORM CEMENT LAYER
Vyčichl, J.
;
Jíra, J.
The article deals with contact stress analysis of pelvic bone after implantation of cemented acetabular component with imperfections of cemented layer. 3D high resolution [...]
Detailed record
-
Similar records
19.
(85)
Original version of the author's contribution as presented on CD, BIO. :
PDF
Parametric study of acetabular cup migration
Jírová, J.
;
Pokorný, D.
The paper deals with loosening and migration of acetabular cup into the pelvis that belongs to the most serious therapeutic complications arising sometimes several months [...]
Detailed record
-
Similar records
20.
(100)
Original version of the author's contribution as presented on book, page 523. :
PDF
STRESS ANALYSIS OF BURCH-SCHNEIDER CAGE
Řehák, K.
;
Matug, M.
This article deals with the stress analysis of the Burch-Schneider (BS) cage as applied to a hip joint. Due to the complex geometry of the solved problem, material proper [...]
Detailed record
-
Similar records
Haven't found what you were looking for? Try your search on other servers:
recid:1959 in Amazon
recid:1959 in CERN EDMS
recid:1959 in CERN Indico
recid:1959 in CERN Intranet
recid:1959 in CiteSeer
recid:1959 in Google Books
recid:1959 in Google Scholar
recid:1959 in Google Web
recid:1959 in IEC
recid:1959 in IHS
recid:1959 in INSPEC
recid:1959 in INSPIRE
recid:1959 in ISO
recid:1959 in KISS Books/Journals
recid:1959 in KISS Preprints
recid:1959 in NEBIS
recid:1959 in SLAC Library Catalog