guest ::
login
The Institute of Theoretical and Applied Mechanics
Search
Submit
Personalize
Your alerts
Your baskets
Your searches
Help
Home
> Search Results: recid:3320
Search:
any field
abstract
affiliation
author
author count
authority author
authority institute
authority journal
authority subject
caption
cataloguer nickname
cited by
cited by excluding self cites
coden
collaboration
collection
date created
date modified
division
doi
exact author
exact first author
exact title
experiment
file type
first author
fulltext
isbn
issn
item count
journal
keyword
miscellaneous
record ID
reference
reference to
refers to
refers to excluding self cites
report number
restriction
subject
title
year
Search Tips
::
Advanced Search
Search collections:
*** any public collection ***
Administrative Reports
Author Works
Author Works for Approval
ITAM Library
Company Publications
Company Publications for Appro...
Conference Contributions
Conference Materials
Conference Materials for Appro...
Conference Proceedings
Conference Programs
eBooks
Essays
Exam Topics
Lecture Notes
Monographs
Papers
Posters
Preprints
Presentations
Proceedings
Product Instructions
Production Catalogues
Project Documents
Reports
Reports for Approval
Research Reports
Sillabi
Study materials
Study Materials for Approval
The Institute of Theoretical a...
Theses
Theses for Approval
Sort by:
Display results:
Output format:
latest first
title
author
report number
year
asc.
desc.
- or rank by -
word similarity
times cited
selfcites
10 results
25 results
50 results
100 results
single list
split by collection
BibTeX
Dublin Core
EndNote
EndNote (8-X)
HTML brief
HTML citesummary
HTML detailed
MARC
MARCXML
MODS
NLM
photo captions only
portfolio
RefWorks
Untitled
The Institute of Theoretical and Applied Mechanics
20
records found 1 - 10
jump to record:
Search took 0.03 seconds.
1.
(75)
Original version of the author's contribution as presented on CD, BIO. :
PDF
Comparison of mechanical aspects of different treatment methods of human finger tendon contractures
Kult, J.
;
Jírová, J.
The article reports on an analysis of conservative treatment methods of finger flexor contractures (splinting and external fixation). The treatment simulation is based on [...]
Detailed record
-
Similar records
2.
(75)
Original version of the author's contribution as presented on CD, . :
PDF
One-dimensional mathematical model of the flow through a collapsible tube with applications to blood flow through human vessels
Štembera, V.
;
Chlup, H.
The simulation of the fluid flow through elastic pipes has a great application in a blood flow through human vessels – investigation of such phenomena as an atherioscle [...]
Detailed record
-
Similar records
3.
(75)
Original version of the author's contribution as presented on book, page 523. :
PDF
STRESS ANALYSIS OF BURCH-SCHNEIDER CAGE
Řehák, K.
;
Matug, M.
This article deals with the stress analysis of the Burch-Schneider (BS) cage as applied to a hip joint. Due to the complex geometry of the solved problem, material proper [...]
Detailed record
-
Similar records
4.
(76)
Original version of the author's contribution as presented on CD, BIO. :
PDF
Fe model of the human vocall folds considering fluid structure interaction
Švancara, P.
;
Hrůza, V.
The study presents three-dimensional finite element (FE) model of flow induced oscillations of the human vocal folds in interaction with acoustic processes in the simplif [...]
Detailed record
-
Similar records
5.
(76)
Original version of the author's contribution as presented on CD, . :
PDF
Stress - strain analyse of vertebral segment
Hudeček, D.
;
Florian, Z.
This paper deals with implementation stress-strain analysis of the lumbar segment of the human vertebral. Individual vertebral elements are modelled base on the 4. and th [...]
Detailed record
-
Similar records
6.
(76)
Original version of the author's contribution as presented on CD, . :
PDF
HOMOGENIZATION APPLIED IN MODELLING SMOOTH MUSCLE TISSUE
Rohan, E.
Abstrakt: The paper deals with the homogenization method in the context of modelling biological tissues which undergo large deformation. The updated Lagrangian scheme is [...]
Detailed record
-
Similar records
7.
(76)
Original version of the author's contribution as presented on book, page 627. :
PDF
RELATIONS BETWEEN FRACTAL DIMENSION AND VOLUME OF TRABECULAR BONE AND ITS BEHAVIOUR UNDER LOADING
Topoliński, T.
;
Jung, S.
Two parameters of bone microarchitecture: volume of bone layer and fractal dimension were used. 42 human bone samples were cut to cylindrical testing samples of 8.5 mm th [...]
Detailed record
-
Similar records
8.
(77)
Original version of the author's contribution as presented on CD, BIO. :
PDF
Finite element model of human skull for investigation of extreme stress state
Jíra, J.
;
Jírová, J.
The article reports on development of finite element models of human skull used in investigation of extreme stress state during a traffic accident. The procedures used in [...]
Detailed record
-
Similar records
9.
(77)
Original version of the author's contribution as presented on CD, KEY. :
PDF
Fundamental dynamic characteristics of human skull
Horáček, J.
;
Vokřál, J.
The contribution presents experimental investigation of the frequency modal, damping and stress wave propagation characteristics and finite element (FE) mode ling of the [...]
Detailed record
-
Similar records
10.
(77)
Original version of the author's contribution as presented on CD, . :
PDF
Physical model of the human bloodstream system resistance – experimental evaluation
Chlup, H.
;
Konvičková, S.
Experimental line for measuring velocity of the pulse wave in vessels (aorta) using invasive or noninvasive methods is designed in the Laboratory of human biomechanics, C [...]
Detailed record
-
Similar records
11.
(78)
Original version of the author's contribution as presented on CD, . :
PDF
Stress-strain analyses of total knee replacement
Budinszky, C.
;
Florian, Z.
The development of optimal total knee replacement routes to keep all funcitons of knee joint by a surgical implant with the simpliest construction. Its mainattributes are [...]
Detailed record
-
Similar records
12.
(78)
Original version of the author's contribution as presented on CD, . :
PDF
Explicit finite element analysis of human head impacting a rigid surface
Jiroušek, O.
Article deals with explicit finite element modelling of contact conditions of human head impacting a flat rigid surface. For this purpose, detailed 3-D model of human s [...]
Detailed record
-
Similar records
13.
(80)
Original version of the author's contribution as presented on CD, . :
PDF
MODELLING OF THE VIBRATION PROPERTIES OF THE HUMAN VOCAL FOLDS
Vampola, T.
;
Klepáček, I.
A 3D finite element model of the human larynx including the vocal folds was developed. The model enables to take into account phonation position (tension and adduction) o [...]
Detailed record
-
Similar records
14.
(80)
Original version of the author's contribution as presented on CD, BIO. :
PDF
Treatment of extra-articular fracture following total knee arthroplasty
Křen, J.
;
Koudela, K.jr.
Fractures of distal femur following total knee arthroplasty (TKA) are infrequent, but devastating complications. They require anatomically stable internal fixation. The s [...]
Detailed record
-
Similar records
15.
(80)
Original version of the author's contribution as presented on book, page 115. :
PDF
PORE SIZE DISTRIBUTION OF HUMAN TRABECULAR BONE – COMPARISON OF INTRUSION MEASUREMENTS WITH IMAGE ANALYSIS
Doktor, T.
;
Jiroušek, O.
This paper deals with pore size distribution assessment in trabecular structure of human proximal femur. Two different approaches for estimation of histograms of pore siz [...]
Detailed record
-
Similar records
16.
(80)
Original version of the author's contribution as presented on book, page 379. :
PDF
CREATION OF COMPUTATIONAL MODELS OF CANCELLOUS BONE
Marcián, P.
;
Navrátil, P.
The paper deals with a creation of computational model of cancellous bone. Cancellous bone is inner porous part of bones and it is of a very complex geometry. It is compo [...]
Detailed record
-
Similar records
17.
(80)
Original version of the author's contribution as presented on CD, poster. :
PDF
Frequency response functions modelling of the human skull with simulation of brain tissue influence
Pešek, L.
;
Hendrych, P.
Abstrakt:
Detailed record
-
Similar records
18.
(82)
Original version of the author's contribution as presented on book, page 247. :
PDF
MICROSTRUCTURAL MODELS OF TRABECULAR BONE COMPARISON OF CT-BASED FE MODELS
Jiroušek, O.
;
Zlámal, P.
In the article a detailed comparison of techniques used to develop detailed FE models of trabecular bone microstructure is presented. The FE models are built using a stac [...]
Detailed record
-
Similar records
19.
(82)
Original version of the author's contribution as presented on CD, . :
PDF
BONE TISSUE MODELLING BASED ON THE ORTHOTROPIC MICROPOLAR CONTINUUM
Rosenberg, Josef
;
Nováček, Vit
Abstrakt: The paper deals with the bone tissue modelling as a micropolar continuum. Isotropic and orthotropic constitutive relations were used for the description of the [...]
Detailed record
-
Similar records
20.
(100)
Original version of the author's contribution as presented on CD, . :
PDF
Comperative study of FE models of human femur constructed by different approaches
Kytýř, D.
;
Jiroušek, O.
Methods for fullyautomatic generation of FE model are shortly discussed in the paper. There are two basic principles of reconstruction [...]
Detailed record
-
Similar records
Haven't found what you were looking for? Try your search on other servers:
recid:3320 in Amazon
recid:3320 in CERN EDMS
recid:3320 in CERN Indico
recid:3320 in CERN Intranet
recid:3320 in CiteSeer
recid:3320 in Google Books
recid:3320 in Google Scholar
recid:3320 in Google Web
recid:3320 in IEC
recid:3320 in IHS
recid:3320 in INSPEC
recid:3320 in INSPIRE
recid:3320 in ISO
recid:3320 in KISS Books/Journals
recid:3320 in KISS Preprints
recid:3320 in NEBIS
recid:3320 in SLAC Library Catalog