Comparison of heat transfer in a straight and helical tube and influence of preset singularities on heat transfer in a straight tube at the flow of surfactant solutions


Abstract eng:
Experiments were made on a hydraulic facility with closed loop. The influence of a preset valve and circular bend 180° on the heat transfer along the 16 mm tube was investigated. Three different concentrations of cationic surfactant Arquad S 50 (oleyltrimethylammonium chloride) in mixture with NaSal (sodium salicylate) were experimented with. The range of Reynolds numbers was 8.000100.000 and the heat flux through the tube wall was 22 and 40 kW/m2.

Contributors:
Publisher:
Institute of Theoretical and Applied Mechanics, AS CR, v.v.i., Prague
Conference Title:
Conference Title:
ENGINEERING MECHANICS 2006
Conference Venue:
Svratka (CZ)
Conference Dates:
2006-05-15 / 2006-05-18
Rights:
Text je chráněný podle autorského zákona č. 121/2000 Sb.



Record appears in:

 Record created 2014-11-12, last modified 2014-11-18


Original version of the author's contribution as presented on CD, , paper No. 208. :
Download fulltext