Ionic concentration changes in the tubular system of rat ventricular cardiac cell model


Abstract eng:
We present a design of a model of rat ventricular cardiomyocyte with transverse-axial tubular system and the results of the first simulations of tubular ionic concentration changes at different stimulation rates. The morphology of tubular system and the distribution of ionic channels in tubular membrane were described to meet the recent data of Soeller and Cannell (1999) and of Orchard's group in Leeds. Exploration of activity-dependent changes in tubular ionic concentrations revealed an increase in relative Ca2+ depletion from 7.3 % to 14 % when increasing the stimulation frequency from 1 Hz to 5 Hz. Meanwhile, relative K+ accumulation decreased from 4.3 % to 3 %. These effects led to a limitation of intracellular Ca2+ overload.

Contributors:
Publisher:
Institute of Thermomechanics AS CR, v.v.i., Prague
Conference Title:
Conference Title:
Engineering Mechanics 2004
Conference Venue:
Svratka (CZ)
Conference Dates:
2004-05-10 / 2004-05-13
Rights:
Text je chráněný podle autorského zákona č. 121/2000 Sb.



Record appears in:

 Record created 2014-11-14, last modified 2014-11-18


Original version of the author's contribution as presented on CD, . :
Download fulltext
PDF

Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)