Effect of Inaccuracy of Isolation Detailing on Overturning Resistant Capacity of Seismic Isolated Building


Abstract eng:
This paper presents an analysis of effect of isolation detailing inaccuracy on the overturning resistant capacity of seismic isolated buildings subject to bidirectional earthquake excitation using hysteretic model. Several typical sources of inaccuracy in isolation detailing were expounded based on the author’s investigation. Dynamic analysis was performed for both time domain response and random response, and an antioverturning moment ratio which is defined in engineering design is employed to judge the overturning capacity of the isolated structure ηAOj=MAj/MOj The numerical result shows that the inaccuracy of isolation detailing should be taken into account for determining the limit value of the height to width ratio of isolated buildings.

Contributors:
Publisher:
Research Publishing, No:83 Genting Lane, #08-01, Genting Building, 349568 SINGAPORE
Conference Title:
Conference Title:
5th Asian-Pacific Symposium on Structural Reliability and its Applications
Conference Venue:
Singapore (SG)
Conference Dates:
2012-05-23 / 2012-05-25
Rights:
Text je chráněný podle autorského zákona č. 121/2000 Sb.



Record appears in:



 Record created 2014-11-18, last modified 2014-11-18


Original version of the author's contribution as presented on CD, .:
Download fulltext